DHP 5.3
YES
5.3 m³/h
700 rpm
1800 rpm
80 Bar
M42 x1.5, M42 x 1.5, Depth 22mm
Duplex / Super Duplex Stainless Steel
Availability: | |
---|---|
Quantity: | |
The reverse osmosis desalination pump DHP5.3 is fixed displacement axial piston pump in which the flow is proportional to the number of revolutions of the input shaft and the pump displacement, regardless of any counter-pressure.
DHP series ro high pressure pumps are designed to supply low viscosity and corrosive fluids under high pressure, e.g., in seawater reverse osmosis filtration applications and for high-pressure salt-water pumping.
DHP series ro high pressure pumps are based on the axial piston principle enabling a very light and compact design, and they are designed so that lubrication of the moving parts in the pumps is provided by the fluid itself. No oil lubrication is thus required. All parts included in the DHP ro high pressure pumps are designed to provide long service life, i.e., long service life with a constantly high efficiency and minimum of service required.
✔ Maintenance free due to water lubrication and direct drive (no belt or gearbox)
✔ High efficiency compared to any other pump on the market
✔ Small, compact and light design
✔ Small pulsation, no need for pulsation dampeners
✔ Wide speed control range
✔ Stainless steel design duplex (SAF 2205 / EN 1.4462 / UNS 31803) and super duplex (SAF 2507 / EN 1.4410 / UNS 32507) stainless steel
✔ Usually driven by an electric motor with coupling between pump and motor.
• Coal Mine Wastewater
• Zero Liquid Discharge of Wastewater
• Seawater Desalination
• Landfill leachate
Name | DHP 5.3 ro high pressure pump |
Stock Status | Usually Ships in 4 to 6 Weeks |
Weight | 32KG |
Country of Origin | China |
Email For Price | YES |
Related Products | Please go to DHP category |
sea water desalination pump DHP5.3
water desalination pump DHP5.3
seawater reverse osmosis system
sea water reverse osmosis system
The reverse osmosis desalination pump DHP5.3 is fixed displacement axial piston pump in which the flow is proportional to the number of revolutions of the input shaft and the pump displacement, regardless of any counter-pressure.
DHP series ro high pressure pumps are designed to supply low viscosity and corrosive fluids under high pressure, e.g., in seawater reverse osmosis filtration applications and for high-pressure salt-water pumping.
DHP series ro high pressure pumps are based on the axial piston principle enabling a very light and compact design, and they are designed so that lubrication of the moving parts in the pumps is provided by the fluid itself. No oil lubrication is thus required. All parts included in the DHP ro high pressure pumps are designed to provide long service life, i.e., long service life with a constantly high efficiency and minimum of service required.
✔ Maintenance free due to water lubrication and direct drive (no belt or gearbox)
✔ High efficiency compared to any other pump on the market
✔ Small, compact and light design
✔ Small pulsation, no need for pulsation dampeners
✔ Wide speed control range
✔ Stainless steel design duplex (SAF 2205 / EN 1.4462 / UNS 31803) and super duplex (SAF 2507 / EN 1.4410 / UNS 32507) stainless steel
✔ Usually driven by an electric motor with coupling between pump and motor.
• Coal Mine Wastewater
• Zero Liquid Discharge of Wastewater
• Seawater Desalination
• Landfill leachate
Name | DHP 5.3 ro high pressure pump |
Stock Status | Usually Ships in 4 to 6 Weeks |
Weight | 32KG |
Country of Origin | China |
Email For Price | YES |
Related Products | Please go to DHP category |
sea water desalination pump DHP5.3
water desalination pump DHP5.3
seawater reverse osmosis system
sea water reverse osmosis system
In order to extend the service life of the high pressure water pump and maintain its pumping stability, please make sure that the medium working condition is consistent with the required working condition. In order to avoid particle wear on the high pressure water pump, it is recommended to install an appropriate filter before it.
The main filter must filter 99.98% of particles above 10μm
It is recommended that you install a low-pressure protection switch before the ro high pressure pump inlet. Please refer to the parameter table in the technical specifications of the high pressure water pump for the minimum inlet pressure of different types of pumps; Ensure that the inlet pipe is not smaller than the inlet diameter of the high-pressure water pump.
If the high pressure water pump is used with a frequency converter, the frequency converter is required to be heavy-load constant torque, and the starting mode is constant torque starting. If the special frequency converter for water pump fan is not constant torque, it may not be able to drive the positive displacement water pump; For example, ABB's ACS510 series inverter may not be able to drive the DHP high pressure water pump. The same is true for other brands of water pump and fan-specific inverters, please pay attention to communicate with the inverter manufacturers for selection.
Please pay attention to the continuous inlet pressure, maximum peak inlet pressure, maximum continuous outlet pressure, and minimum outlet pressure operating ranges of different types of high-pressure water pumps. For details, please refer to the parameter table in the high-pressure pump technical specification. Ensure that the pressure when the high pressure water pump is running does not exceed the range required by the specification.
Before starting the pump, it is recommended that you thoroughly flush the pipeline and system to remove any residues or foreign objects that may be present. It is strongly recommended that you drain the air from the pump and system.
Test whether the direction of the ro high pressure pump is consistent with the arrow mark on the pump. “I” represent the inlet of the high-pressure water pump, and “O” represents the outlet of the high pressure water pump.
For a short shutdown of the high pressure water pump within 3 days, there is no need to flush while keeping the pump full of overflow medium.
If the high pressure water pump has been shut down for more than 3 days, it is recommended that you flush the pump with fresh water. When the high pressure water pump has been shut down for more than 15 days, it is recommended that you flush the pump with fresh water containing fungicides.
If the high pressure water pump is running under conditions of high salt content, it is recommended that you flush the pump with fresh water every time you stop.
If the pump is running under conditions of high salt content, it is recommended that you flush the pump with fresh water every time you stop it.
If abnormal noise and vibration occur during the operation of the pump, please stop the high pressure piston pump immediately and perform maintenance on it.
It is forbidden to start the high pressure piston pump when the rear valve is closed, otherwise it will cause the safety valve to work, or even the pipeline burst.
It is recommended that the pump outlet adopt a flexible connection method of high-pressure hose.
In order to extend the service life of the high pressure water pump and maintain its pumping stability, please make sure that the medium working condition is consistent with the required working condition. In order to avoid particle wear on the high pressure water pump, it is recommended to install an appropriate filter before it.
The main filter must filter 99.98% of particles above 10μm
It is recommended that you install a low-pressure protection switch before the ro high pressure pump inlet. Please refer to the parameter table in the technical specifications of the high pressure water pump for the minimum inlet pressure of different types of pumps; Ensure that the inlet pipe is not smaller than the inlet diameter of the high-pressure water pump.
If the high pressure water pump is used with a frequency converter, the frequency converter is required to be heavy-load constant torque, and the starting mode is constant torque starting. If the special frequency converter for water pump fan is not constant torque, it may not be able to drive the positive displacement water pump; For example, ABB's ACS510 series inverter may not be able to drive the DHP high pressure water pump. The same is true for other brands of water pump and fan-specific inverters, please pay attention to communicate with the inverter manufacturers for selection.
Please pay attention to the continuous inlet pressure, maximum peak inlet pressure, maximum continuous outlet pressure, and minimum outlet pressure operating ranges of different types of high-pressure water pumps. For details, please refer to the parameter table in the high-pressure pump technical specification. Ensure that the pressure when the high pressure water pump is running does not exceed the range required by the specification.
Before starting the pump, it is recommended that you thoroughly flush the pipeline and system to remove any residues or foreign objects that may be present. It is strongly recommended that you drain the air from the pump and system.
Test whether the direction of the ro high pressure pump is consistent with the arrow mark on the pump. “I” represent the inlet of the high-pressure water pump, and “O” represents the outlet of the high pressure water pump.
For a short shutdown of the high pressure water pump within 3 days, there is no need to flush while keeping the pump full of overflow medium.
If the high pressure water pump has been shut down for more than 3 days, it is recommended that you flush the pump with fresh water. When the high pressure water pump has been shut down for more than 15 days, it is recommended that you flush the pump with fresh water containing fungicides.
If the high pressure water pump is running under conditions of high salt content, it is recommended that you flush the pump with fresh water every time you stop.
If the pump is running under conditions of high salt content, it is recommended that you flush the pump with fresh water every time you stop it.
If abnormal noise and vibration occur during the operation of the pump, please stop the high pressure piston pump immediately and perform maintenance on it.
It is forbidden to start the high pressure piston pump when the rear valve is closed, otherwise it will cause the safety valve to work, or even the pipeline burst.
It is recommended that the pump outlet adopt a flexible connection method of high-pressure hose.